A hydraulic jump is the exam's favourite open-channel trap in disguise: it looks like a specific-energy problem, but the depths before and after it do not share one energy value. Learn the Bélanger equation, the jump-classification table, and the energy-loss shortcut, and the whole family of jump questions collapses to three lines of arithmetic.
Last reviewed: 2026-11-07. Every worked number below was independently re-solved; steps are shown in full.
What a hydraulic jump is — and why it only runs one way
Supercritical flow is fast, shallow, and unstable: it cannot stay supercritical once the downstream condition (a flatter slope, a deeper tailwater, a gate, a basin) forces it to slow down. Because a gradual transition from supercritical to subcritical is impossible — the flow would have to pass through critical depth with no mechanism to do it smoothly — the depth snaps up across a short, violent roller. That snap is the jump. It is why jumps sit at the toe of spillways, below sluice gates, and in stilling basins: engineers put them there on purpose, to burn off erosive energy before it reaches an unprotected channel bed.
The reverse never happens as a jump. Subcritical flow becoming supercritical — over a weir crest, down a steep chute — is a gradual acceleration with falling depth, not a roller. If a question stem describes depth falling abruptly, it is not describing a hydraulic jump.
The Bélanger equation: where sequent depth comes from
Across the short length of a jump, wall friction is negligible, so momentum (specific force) is conserved even though energy is not. Equating the specific force upstream and downstream for a horizontal rectangular channel, with continuity Q constant, gives the Bélanger equation:
\[\frac{y_{2}}{y_{1}} = \frac{1}{2} (−1 + \sqrt{1 + 8 F_{r1}^{2}})\] \[F_{r1} = \frac{V_{1}}{\sqrt{g \cdot y_{1}}}\]
| \(q = \frac{Q}{b}\) | discharge per unit width — the rectangular-channel shortcuts need q, not total Q |
|---|---|
| g | \(32.2\,\text{ft}/\text{s}^{2}\) in US units, \(9.81\,\text{m}/\text{s}^{2}\) in SI — the single most common unit slip on this topic |
| horizontal, rectangular | the closed form assumes a horizontal rectangular channel; sloped or non-rectangular sections need the general momentum equation |
Worked backwards, the equation also solves the reverse exam question: given both sequent depths, the ratio \(\frac{y_{2}}{y_{1}}\) fixes \(Fr_{1}\) (Worked Problem 3 below). And because energy is not conserved, the energy loss must be computed separately — from \(E_{1} - E_{2}\), or from the rectangular shortcut \(\Delta E = \frac{(y_{2} - y_{1})^{3}}{(4 \cdot y_{1} \cdot y_{2})}\), which is the same number and a free arithmetic check.
Classifying the jump from Fr1
The incoming Froude number fixes the jump's character — and exam stems love asking for the classification as a one-line follow-up after the sequent depth. The standard bands are:
| \(1 < Fr_{1} < 1.7\) | Undular jump — a train of small standing waves, very little energy dissipated |
|---|---|
| \(1.7 \le Fr_{1} < 2.5\) | Weak jump — a smooth rise with small rollers |
| \(2.5 \le Fr_{1} < 4.5\) | Oscillating jump — an unstable jet that oscillates from bed to surface; hard to contain |
| \(4.5 \le Fr_{1} \le 9\) | Steady jump — a stable, well-contained roller; the range stilling basins are designed for |
| \(Fr_{1} > 9\) | Strong jump — violent, rough, with heavy spray and air entrainment |
Rule of thumb for the design-flavoured question: if the stem asks which jump a stilling basin wants, the answer is the steady jump \((Fr_{1} roughly 4.5–9)\) — it dissipates the most energy in the shortest, most predictable roller. The oscillating band is the one to avoid: its wandering jet scours unpredictably.
Worked problem 1 Sequent depth and jump type (FE pace, US units)
Given: a horizontal rectangular channel, \(b = 8\,\text{ft}\), carries \(Q = 96\) cfs at an upstream depth \(y_{1} = 1.00\,\text{ft}\) (supercritical). Find the sequent depth \(y_{2}\), the energy loss, and the jump type.
Solution:
- Discharge per unit width: \(q = \frac{Q}{b} = \frac{96}{8}\) = 12.0 cfs/ft
- \(V_{1} = \frac{q}{y_{1}} = \frac{12.0}{1.00} = 12.00\,\text{ft}/\text{s}\)
- \(Fr_{1} = \frac{V_{1}}{\sqrt{g \cdot y_{1}}} = \frac{12.00}{\sqrt{32.2 \times 1.00}} = \frac{12.00}{5.6745}\) = 2.115 (supercritical, as stated)
- \(y_{2} = (\frac{y_{1}}{2}) (−1 + \sqrt{1 + 8 \cdot Fr_{1}^{2}}) = 0.50 \times (−1 + \sqrt{1 + 8 \times 4.472}) = 0.50 \times (−1 + 6.064)\) = 2.532 ft
- \(E_{1} = y_{1} + \frac{V_{1}^{2}}{2 g} = 1.00 + \frac{144}{64.4} = 1.00 + 2.236 = 3.236\,\text{ft}\); \(V_{2} = \frac{q}{y_{2}} = \frac{12.0}{2.532} = 4.739\,\text{ft}/\text{s}\); \(E_{2} = 2.532 + \frac{(4.739)^{2}}{64.4} = 2.532 + 0.349 = 2.881\,\text{ft}\)
- \(\Delta E = E_{1} - E_{2} = 3.236 - 2.881\) = 0.355 ft. Shortcut check: \(\frac{(2.532 - 1.00)^{3}}{(4 \times 1.00 \times 2.532)} = \frac{3.596}{10.128} = 0.355\) ✓
- Classification: \(Fr_{1} = 2.11\) falls in 1.7–2.5, so this is a weak jump.
Answer: \(y_{2} \approx 2.53\,\text{ft}\), energy loss ≈ 0.355 ft, weak jump. Trap note: the shortcut agreeing to three decimals is your arithmetic check — but show the \(E_{1} - E_{2}\) route on the exam; it is the one that generalises beyond rectangular channels.
Worked problem 2 Power dissipated in the jump (PE pace, US units)
Given: a horizontal rectangular channel, \(b = 12\,\text{ft}\), carries \(Q = 240\) cfs at \(y_{1} = 1.20\,\text{ft}\). Find \(y_{2}\), the energy loss, the power dissipated, and the jump type.
Solution:
- \(q = \frac{Q}{b} = \frac{240}{12}\) = 20.0 cfs/ft; \(V_{1} = \frac{20.0}{1.20} = 16.667\,\text{ft}/\text{s}\)
- \(Fr_{1} = \frac{16.667}{\sqrt{32.2 \times 1.20}} = \frac{16.667}{6.216}\) = 2.681
- \(y_{2} = 0.60 \times (−1 + \sqrt{1 + 8 \times 7.189}) = 0.60 \times (−1 + 7.649)\) = 3.990 ft
- \(E_{1} = 1.20 + \frac{(16.667)^{2}}{64.4} = 1.20 + 4.313 = 5.513\,\text{ft}\); \(V_{2} = \frac{20.0}{3.990} = 5.013\,\text{ft}/\text{s}\); \(E_{2} = 3.990 + \frac{(5.013)^{2}}{64.4} = 3.990 + 0.390 = 4.380\,\text{ft}\)
- \(\Delta E = 5.513 - 4.380\) = 1.133 ft \((shortcut: \frac{(3.990 - 1.20)^{3}}{(4 \times 1.20 \times 3.990)} = 1.133 ✓)\)
- Power dissipated: \(P = \gamma \cdot Q \cdot \Delta E = 62.4 \times 240 \times 1.133\) = 16,970 \(\text{lb} - \frac{\text{ft}}{s} \approx 30.9\,\text{hp}\) \((1 \text{hp} = 550\,\text{lb}-\frac{\text{ft}}{s})\)
- Classification: \(Fr_{1} = 2.68\) falls in 2.5–4.5, so this is an oscillating jump — the band a designer would try to avoid for a stilling basin.
Answer: \(y_{2} \approx 3.99\,\text{ft}\), energy loss ≈ 1.13 ft, power dissipated ≈ 30.9 hp, oscillating jump. Trap note: power uses the total discharge Q (240 cfs), not q — and the specific weight \(\gamma = 62.4\,\text{lb}/\text{ft}^{3}\) in US units, not the mass density.
Worked problem 3 The reverse question: given both sequent depths (SI units)
Given: a hydraulic jump in a horizontal rectangular channel has sequent depths \(y_{1} = 0.30\,\text{m}\) and \(y_{2} = 1.50\,\text{m}\). Find the upstream Froude number, the energy loss, and the jump type.
Solution:
- Depth ratio: \(\frac{y_{2}}{y_{1}} = \frac{1.50}{0.30}\) = 5.00
- Bélanger backwards: \(5 = \frac{1}{2} (−1 + \sqrt{1 + 8 \cdot Fr_{1}^{2}}) \rightarrow \sqrt{1 + 8 \cdot Fr_{1}^{2}} = 11 \rightarrow 1 + 8 \cdot Fr_{1}^{2} = 121 \rightarrow Fr_{1}^{2} = 15 \rightarrow Fr_{1}\) = 3.873
- \(\Delta E = \frac{(y_{2} - y_{1})^{3}}{(4 \cdot y_{1} \cdot y_{2})} = \frac{(1.20)^{3}}{(4 \times 0.30 \times 1.50)} = \frac{1.728}{1.80}\) = 0.960 m
- Classification: \(Fr_{1} = 3.87\) falls in 2.5–4.5, so this is an oscillating jump.
Answer: \(Fr_{1} \approx 3.87\), energy loss ≈ 0.96 m, oscillating jump. Trap note: this reverse form needs no discharge at all — if you start hunting for Q, you are solving the wrong problem. The ratio alone fixes \(Fr_{1}\).
Worked problem 4 Jump height and stilling-basin length (design estimate)
Given: the jump from Worked Problem \(1 (y_{1} = 1.00\,\text{ft}, y_{2} = 2.53\,\text{ft})\). Estimate the height of the jump and the length a stilling basin must provide.
Solution:
- Height of jump: \(h_{j} = y_{2} - y_{1} = 2.532 - 1.00\) = 1.53 ft
- Jump length (empirical): \(L_{j} \approx 6 \cdot y_{2} = 6 \times 2.532\) = 15.2 ft; the USBR value \(6.1 \cdot y_{2}\) gives 15.4 ft, and the practical range 5–\(7 \cdot y_{2}\) gives 12.7–17.7 ft
Answer: jump height ≈ 1.53 ft; allow roughly 15 ft of basin (12.7–17.7 ft by the 5–\(7 \cdot y_{2}\) range). Trap note: jump length is an estimate, not a conservation law — if a multiple-choice stem offers a suspiciously precise length, it is the \(6 \cdot y_{2}\) value, and the distractors are usually the height \((1.53\,\text{ft})\) or a length computed from \(y_{1}\) instead of \(y_{2}\).
Frequently asked questions
What is a hydraulic jump?
A hydraulic jump is the abrupt transition from supercritical flow (fast, shallow, Fr > 1) to subcritical flow (slow, deep, Fr < 1) in an open channel. Depth rises sharply across a short, turbulent roller, and much of the flow energy is dissipated as heat and turbulence. Engineers deliberately force jumps in stilling basins below spillways and sluice gates to protect the channel bed from erosion.
What are sequent (conjugate) depths?
The depths before and after a hydraulic jump: y1 upstream, y2 downstream, related by the Bélanger equation y2/y1 = ½(−1 + √(1 + 8·Fr1²)) for a horizontal rectangular channel. They are not alternate depths — alternate depths share one specific energy, while sequent depths have different energies because the jump dissipates energy.
How is energy loss across a hydraulic jump computed?
Compute the specific energy at each sequent depth and take the difference: ΔE = E1 − E2. For a rectangular channel, the shortcut ΔE = (y2 − y1)³/(4·y1·y2) gives the same answer — useful as an arithmetic check.
How is a hydraulic jump classified by Froude number?
By the upstream Froude number: undular (1–1.7), weak (1.7–2.5), oscillating (2.5–4.5), steady (4.5–9), strong (above 9). Stilling basins aim for the steady range; the oscillating range is the one to avoid.
What is the length of a hydraulic jump?
An empirical estimate: Lj ≈ 6·y2 (about 6.1·y2 by the USBR recommendation for strong jumps), with a practical range of roughly 5–7 times the sequent depth. It is a design estimate, not an exact value.