Theory explainer
Venturi Meter Problems — FE/PE Civil Exam Worked Examples
A Venturi meter measures flow with nothing but a pressure difference. Squeeze a pipe down to a throat, the flow speeds up, the pressure falls, and the size of that fall tells you the discharge — no moving parts, no electronics, just Bernoulli’s equation and continuity. The exam loves the device for exactly that reason: the whole problem is one derivation, one manometer conversion, and one careful pass through the units, and every trap in the topic lives in one of those three steps. Use a pressure difference as a head without converting it, read a mercury deflection as the head difference itself, add an elevation difference the manometer already accounts for, or mix inches with feet in the areas, and the answer is wrong by a factor that looks plausible. Every problem below is the same formula; the skill is the setup.
Last reviewed: 2026-11-10. Every worked number below was independently re-solved; steps are shown in full.
The Venturi idea: Bernoulli plus continuity
A Venturi meter is a pipe that narrows smoothly to a throat and then widens again: a short convergent cone, a short throat, and a long divergent cone, with a pressure tapping at the inlet and one at the throat. The flow is steady and (for the exam) incompressible, so continuity holds at the two sections: Q = A1V1 = A2V2, and the throat velocity is the inlet velocity scaled up by the area ratio, V2 = V1(A1/A2). Bernoulli between the same two sections, for a horizontal meter where z1 = z2, says p1/γ + V1²/2g = p2/γ + V2²/2g, so the pressure-head difference is exactly the velocity-head gain: h = (p1 − p2)/γ = (V2² − V1²)/2g. Eliminate the velocities with continuity and the discharge falls out: Q = A1A2√(2gh) / √(A1² − A2²). Real flow loses a little energy to friction and the velocity profile is not perfectly uniform, so the theoretical discharge is multiplied by the coefficient of discharge Cd, typically 0.95–0.99 for a Venturi and 0.98 in most exam stems. Two features of the device matter for the exam. First, the throat pressure is lower than the inlet pressure — always — because the velocity head gained there has to come from somewhere, and that somewhere is the pressure head. Second, the long divergent cone recovers most of the pressure by slowing the flow gradually: a Venturi meter throws away only a small fraction of the head difference as permanent loss, which is its advantage over an orifice plate, where the flow separates at the sharp edge and the pressure is never recovered. The derivation is in the Continuity, Energy & Momentum page; this page is where the numbers get worked.
Reading the manometer: turning a deflection into h
The discharge formula wants h, the piezometric head difference between the inlet and the throat: h = (p1/γ + z1) − (p2/γ + z2). What the stem usually gives you is something else — a pressure difference, a manometer deflection, or two gauge readings — and the conversion is where the problem is won or lost. There are three cases, and each has its own rule.
Pressure difference given directly. Divide by the specific weight: h = Δp/γ. For water, γ = 62.4 pcf in US units (9.81 kN/m³ in SI), so a 20 kPa difference is 20,000 ÷ 9,810 = 2.04 m of water. For another liquid, divide by its own specific weight — an oil with specific gravity 0.8 has γ = 0.8 × 62.4 = 49.9 pcf, and the same pressure difference is a larger head. Worked Problem 5 is this case in SI units.
U-tube manometer with a heavy fluid. The deflection x is converted by h = x(Sm/S − 1), where Sm is the manometer fluid’s specific gravity and S the flowing liquid’s. Mercury in water is the exam’s standard case: Sm = 13.6, S = 1, so h = 12.6x — a 3 in mercury deflection is 37.8 in, or 3.15 ft, of water head. The factor 12.6 is worth memorising; it is the single most-tested number in the topic after the discharge formula itself. Worked Problem 2 is this case.
Inverted U-tube with a light fluid. Air (or another light fluid) trapped above the liquid gives h = x(1 − Sm/S). For air in water Sm ≈ 0.0012, so h ≈ x — the deflection is very nearly the head difference itself, which is the point of the inverted tube: it reads small head differences that a mercury tube would barely register.
Vertical meters. The manometer equation already contains the elevations, so a differential manometer connected between two tappings reads the piezometric head difference directly, whatever the orientation of the pipe. On a vertical meter the throat sits above (or below) the inlet, and the temptation is to add or subtract that distance from h — do not. The manometer has done it for you. The elevation only enters if the stem gives two separate pressure-gauge readings instead of a manometer deflection: then you must add the z terms yourself, because a gauge reads p/γ, not p/γ + z. Worked Problem 3 is the vertical case, with the wrong answer shown alongside the right one.
The square law, the β form, and the cousins
Three shortcuts and comparisons carry the rest of the topic. The square law: Q grows with √h, so doubling the discharge quadruples the head difference, and doubling the head difference multiplies the discharge by only √2 ≈ 1.414. The exam uses this both ways — a stem that asks for the new deflection at double the flow wants four times the old one, and a candidate who scales linearly is wrong by a factor of two. The β form: writing the area ratio as β = d/D (throat diameter over pipe diameter) gives the compact form Q = CdA2√(2gh) / √(1 − β⁴), which is the form the FE reference handbook carries and the form to use when the stem gives diameters rather than areas. Note the fourth power: with β = 0.5, the denominator is √(1 − 0.0625) = 0.968, so the throat area alone (times Cd and √(2gh)) is already within 3% of the answer — a useful sanity check. The cousins: an orifice meter is the same idea with a sharp plate instead of a smooth contraction — same formula family, but Cd ≈ 0.60–0.65 and a large permanent head loss, because the jet contracts past the plate (the vena contracta) and never recovers; see the Orifice Flow Problems page for the Cc × Cv split. A Pitot tube is different again: it measures velocity at a single point, V = √(2gh), where h is the stagnation head minus the static head. It is a point velocity, not the mean velocity, so multiplying by the pipe area only estimates the discharge — the trap is treating the Pitot reading as the average. A short Pitot check closes the theory section below.
Pitot check (worked in one line): a Pitot tube in a pipe reads a stagnation-minus-static head difference of 0.50 ft of water. The velocity at that point is V = √(2gh) = √(2 × 32.2 × 0.50) = 5.67 ft/s. That is the velocity where the tube sits — at the centreline it is the maximum velocity, not the mean, and the discharge needs the velocity profile (for turbulent flow the mean is roughly 0.8–0.85 of the centreline value; the exam would give the factor rather than expecting you to know it).
Worked problem 1 Discharge from a given head difference (FE pace, US units)
Given: a horizontal Venturi meter has an 8 in inlet diameter and a 4 in throat diameter, and carries water at 60 °F. The piezometric head difference between the inlet and the throat is 2.5 ft, and Cd = 0.98. Find the discharge in cfs and in gpm.
Solution:
- Areas, in square feet — convert the diameters first: D1 = 8/12 = 0.667 ft, D2 = 4/12 = 0.333 ft. A1 = (π/4)(0.667)² = 0.349 ft²; A2 = (π/4)(0.333)² = 0.0873 ft².
- The velocity-head term: √(2gh) = √(2 × 32.2 × 2.5) = √161 = 12.69 ft/s.
- The area combination: A1A2 = 0.349 × 0.0873 = 0.0305 ft⁴; √(A1² − A2²) = √(0.1218 − 0.00762) = √0.1142 = 0.338 ft².
- Q = 0.98 × 0.0305 × 12.69 ÷ 0.338 = 1.12 cfs.
- Convert: 1 cfs = 448.8 gpm, so Q = 1.12 × 448.8 = 503 gpm.
Answer: Q ≈ 1.12 cfs (≈ 503 gpm). Trap note: the diameter-to-area conversion is where this problem is lost — an area computed from an 8 in diameter left in inches is 144 times too large, and the discharge comes out 144 times too large with it. Convert the diameters to feet before squaring, or work the whole problem in inches and convert the discharge at the end. The second trap is Cd: it multiplies the theoretical discharge at the end, and a candidate who divides by it instead gets 1.17 cfs — close enough to look right, wrong by the coefficient.
Worked problem 2 Mercury manometer: the 12.6 factor (FE pace, US units)
Given: a Venturi meter in a 12 in water pipe has a 6 in throat. A mercury U-tube manometer between the inlet and the throat reads a deflection of 3.0 in. Cd = 0.98. Find the discharge.
Solution:
- Convert the deflection to head: h = x(Sm/S − 1) = 3.0 in × (13.6 − 1) = 3.0 × 12.6 = 37.8 in = 3.15 ft of water. This is the step the problem is testing.
- Areas: A1 = (π/4)(1.0)² = 0.785 ft²; A2 = (π/4)(0.50)² = 0.196 ft².
- √(2gh) = √(2 × 32.2 × 3.15) = √202.9 = 14.24 ft/s.
- A1A2 = 0.785 × 0.196 = 0.154 ft⁴; √(A1² − A2²) = √(0.6169 − 0.0386) = √0.5783 = 0.760 ft².
- Q = 0.98 × 0.154 × 14.24 ÷ 0.760 = 2.83 cfs.
Answer: Q ≈ 2.83 cfs. Trap note: the deflection is 3.0 in and the head difference is 3.15 ft — a factor of 12.6 apart, and a candidate who uses 3.0 in as h (0.25 ft) gets Q = 0.80 cfs, nearly four times too small. The mercury factor is the whole problem: the stem gives you a manometer reading precisely so that you convert it, and the conversion is h = 12.6x for mercury in water. The second trap is the same diameter trap as Worked Problem 1 — the 12 in pipe is 1.0 ft, the 6 in throat is 0.50 ft, and the areas follow from the feet, not the inches.
Worked problem 3 Vertical meter: the elevation that cancels (PE pace, US units)
Given: a Venturi meter is mounted in a vertical pipe carrying water upward. The pipe diameter is 10 in, the throat diameter is 5 in, and the throat tapping sits 2 ft above the inlet tapping. A mercury manometer between the tappings reads a deflection of 4.0 in. Cd = 0.98. Find the discharge.
Solution:
- Convert the deflection to the piezometric head difference: h = 4.0 in × 12.6 = 50.4 in = 4.20 ft. The manometer reads the piezometric head difference directly — the 2 ft between the tappings is already accounted for and does not enter.
- Areas: A1 = (π/4)(10/12)² = 0.545 ft²; A2 = (π/4)(5/12)² = 0.136 ft².
- √(2gh) = √(2 × 32.2 × 4.20) = √270.5 = 16.45 ft/s.
- A1A2 = 0.545 × 0.136 = 0.0744 ft⁴; √(A1² − A2²) = √(0.2975 − 0.0186) = √0.2789 = 0.528 ft².
- Q = 0.98 × 0.0744 × 16.45 ÷ 0.528 = 2.27 cfs.
Answer: Q ≈ 2.27 cfs. Trap note: this is the exam’s favourite Venturi trap, and the stem hands you the bait — the 2 ft between the tappings. A candidate who adds it to h gets h = 6.20 ft and Q = 2.76 cfs, about 22% too high. The manometer equation is written in piezometric heads, so the elevation difference between the tappings cancels out of it; the deflection is already the quantity the discharge formula wants. The elevation would only matter if the stem gave two separate gauge pressures instead of a manometer reading — then p/γ alone is not h, and the z terms have to be added by hand.
Worked problem 4 Inverting the equation: the deflection for a given flow (PE pace, US units)
Given: water flows at 2.00 cfs through a 12 in pipe fitted with a 6 in throat Venturi meter, Cd = 0.98. What mercury-manometer deflection will the meter show?
Solution:
- Areas, as in Worked Problem 2: A1 = 0.785 ft², A2 = 0.196 ft², √(A1² − A2²) = 0.760 ft², A1A2 = 0.154 ft⁴.
- Solve the discharge formula for the velocity-head term: √(2gh) = Q × √(A1² − A2²) ÷ (CdA1A2) = 2.00 × 0.760 ÷ (0.98 × 0.154) = 1.521 ÷ 0.151 = 10.06 ft/s.
- Square and solve for h: 2gh = 10.06² = 101.3, so h = 101.3 ÷ (2 × 32.2) = 1.57 ft of water = 18.87 in of water.
- Convert the head back to a mercury deflection: x = h ÷ 12.6 = 18.87 ÷ 12.6 = 1.50 in.
Answer: the manometer reads ≈ 1.50 in of mercury. Trap note: the inversion runs the manometer conversion backwards, and the direction is the trap — the head difference in inches of water is divided by 12.6 to get inches of mercury, not multiplied. A candidate who multiplies gets 238 in of mercury, which is 20 ft of mercury and obviously absurd, and that absurdity is the check: a mercury column that tall would need a manometer taller than the pipe is long. The square-law check also works here: at 2.00 cfs the head is 1.57 ft, so at 4.00 cfs it would be 6.29 ft and the deflection 6.0 in — four times the flow, four times the head, four times the deflection.
Worked problem 5 Discharge from a pressure difference (FE pace, SI)
Given: a horizontal Venturi meter has a 200 mm inlet diameter and a 100 mm throat diameter, and carries water. The pressure difference between the inlet and the throat is 20 kPa. Cd = 0.98. Find the discharge in L/s.
Solution:
- Convert the pressure difference to head: h = Δp/(ρg) = 20,000 ÷ (1,000 × 9.81) = 2.04 m of water.
- Areas: A1 = (π/4)(0.20)² = 0.03142 m²; A2 = (π/4)(0.10)² = 0.007854 m².
- √(2gh) = √(2 × 9.81 × 2.04) = √40.0 = 6.32 m/s.
- A1A2 = 0.03142 × 0.007854 = 2.467 × 10−4 m⁴; √(A1² − A2²) = √(9.870 × 10−4 − 6.169 × 10−5) = √(9.253 × 10−4) = 0.03042 m².
- Q = 0.98 × 2.467 × 10−4 × 6.32 ÷ 0.03042 = 0.0503 m³/s = 50.3 L/s.
Answer: Q ≈ 50.3 L/s. Trap note: the SI version is the same problem with a different conversion — a pressure in kPa is not a head until it is divided by ρg, and the √(2gh) step then works in metres and seconds exactly as it works in feet. The trap is treating 20 kPa as 20 m of head, or dividing by g alone instead of ρg: 20,000 ÷ 9.81 = 2,039 m, which is absurd on its face, and the absurdity is the check. The second trap is the millimetre-to-metre conversion on the diameters — 200 mm is 0.20 m, and an area computed from 200 as if it were metres is a million times too large.
Frequently asked questions
What is a Venturi meter?
A Venturi meter is a pipe fitting that measures discharge by deliberately narrowing the pipe. The flow speeds up through the throat, the pressure falls, and the pressure difference between the inlet and the throat — read as a head difference h — converts directly into discharge through Bernoulli's equation and continuity. A short convergent cone squeezes the flow down, a long divergent cone lets it slow gradually so most of the pressure is recovered, and two pressure tappings (one at the inlet, one at the throat) feed a manometer or pressure gauges. It is the standard flow-measurement device in the FE Civil reference handbook's fluid-mechanics section, and the exam tests it because the whole problem is one derivation plus careful unit handling.
How do you calculate discharge through a Venturi meter?
Q = Cd x A1 x A2 x sqrt(2gh) / sqrt(A1^2 - A2^2), where A1 is the inlet area, A2 the throat area, h the piezometric head difference between inlet and throat, and Cd the discharge coefficient (typically 0.95-0.99 for a Venturi). The formula comes from Bernoulli between the inlet and the throat plus continuity (A1V1 = A2V2). Convert the measured pressure difference to a head of the flowing liquid first, keep diameters and areas in the same units, and apply Cd at the end. Worked Problem 1 runs the full calculation in US units.
How do you read a mercury manometer on a Venturi meter?
The manometer reading is not the head difference h — it has to be converted. For a U-tube manometer with a heavy fluid, h = x x (Sm/S - 1), where x is the deflection, Sm the manometer fluid's specific gravity and S the flowing liquid's. For mercury in water, Sm = 13.6 and S = 1, so h = 12.6x: a 3 in mercury deflection is 37.8 in (3.15 ft) of water head. For an inverted U-tube with a light fluid such as air, h = x x (1 - Sm/S), which is very nearly x itself. Worked Problem 2 runs the mercury conversion, and the traps list covers the candidates who use the deflection as h directly.
Why is the pressure lower at the throat of a Venturi meter?
Because the flow is faster there and Bernoulli's equation trades pressure head for velocity head. Continuity forces the velocity up as the area falls (V2 = V1 x A1/A2), and with the total head conserved the pressure head must fall by exactly the velocity-head gain: h = (V2^2 - V1^2)/2g. The throat pressure is lower, never higher, and the difference grows with the square of the flow — which is why doubling the discharge quadruples the head difference. The long divergent cone then converts most of the velocity head back into pressure, which is the Venturi's advantage over an orifice plate: the same measurement with far less permanent head loss.
Does the elevation difference matter on a vertical Venturi meter?
No — not if the head difference comes from a manometer. The discharge formula needs the piezometric head difference, (p1/gamma + z1) - (p2/gamma + z2), and a differential manometer connected between the two tappings reads exactly that quantity: the elevation of the tappings cancels out of the manometer equation. So on a vertical meter you convert the manometer deflection to h and use it directly, without adding or subtracting the distance between the tappings. Worked Problem 3 is built on this trap: adding the 2 ft between tappings to h inflates the discharge from 2.27 cfs to 2.76 cfs. The elevation only enters if the stem gives you two separate pressure-gauge readings instead of a manometer deflection — then you must add the z terms yourself.
Venturi meter vs orifice meter vs Pitot tube — which does what?
All three measure flow from a pressure difference, but they measure different things. A Venturi meter gives discharge in a pipe, with Cd around 0.95-0.99 and low permanent head loss because the divergent cone recovers pressure. An orifice meter also gives discharge in a pipe, but with Cd around 0.60-0.65 and a large permanent loss, because the flow separates at the sharp plate edge and never recovers. A Pitot tube gives velocity at a single point: V = sqrt(2gh), where h is the stagnation head minus the static head — it measures one velocity, not the mean velocity, so multiplying by the pipe area only estimates the discharge if the profile is known. The exam's favourite comparison is the coefficient: a Venturi near 0.98 against an orifice near 0.61 for the same head.
Free FE/PE flashcards + study tips, by email