Theory explainer
Bearing Capacity Problems — FE/PE Civil Exam Worked Examples
Bearing capacity is the one geotechnical question that always arrives in the same shape: three terms, one table, and a handful of traps. Learn Terzaghi’s equation, the shape factors, the gross-versus-net distinction, and the water-table and local-shear corrections, and the whole family (strip, square, circular, clay, sand, wet, dry) collapses to a few lines each.
Last reviewed: 2026-11-05. Every worked number below was independently re-solved; steps are shown in full.
Terzaghi’s equation and the factor table
Terzaghi (1943) splits the soil’s resistance into three physical parts, read left to right: the cohesion of the soil, the surcharge of the soil sitting above the footing base, and the weight of the soil wedge that must be pushed aside as the footing fails. The bearing-capacity factors Nc, Nq and Nγ depend only on the friction angle φ — they are tabulated in the reference handbook and in the table below, and exam stems that intend a numerical answer either give them or give φ and expect you to look them up.
| φ (°) | Nc | Nq | Nγ |
|---|---|---|---|
| 0 | 5.7 | 1.0 | 0.0 |
| 10 | 9.6 | 2.7 | 1.2 |
| 15 | 12.9 | 4.4 | 2.5 |
| 20 | 17.7 | 7.4 | 5.0 |
| 25 | 25.1 | 12.7 | 9.7 |
| 30 | 37.2 | 22.5 | 19.7 |
| 35 | 57.8 | 41.4 | 42.4 |
| 40 | 95.7 | 81.3 | 100.4 |
Two habits keep the table from biting you. First, always use the factors the stem gives you when it gives them — published Nγ values differ slightly between tables, and the stem’s numbers are the ones its answer choices were built from. Second, at φ = 0 the equation collapses: Nq = 1 and Nγ = 0, so a strip footing on saturated clay gives qult = 5.7c + γDf — the cleanest bearing-capacity question on the exam, and the one in Worked Problem 1.
Shape factors: strip, square, circular
Terzaghi’s equation as written is for a strip footing — a wall footing, long in one direction. A square or circular footing confines the failure wedge on all sides, so it carries more: the cohesion term is multiplied by sc and the self-weight term by sγ, while the surcharge term takes no shape factor at all. Strip: sc = 1.0, sγ = 1.0. Square: sc = 1.3, sγ = 0.8. Circular: sc = 1.3, sγ = 0.6 (with B taken as the diameter). The exam’s favourite distractor here is applying square factors to a strip footing, or applying the 0.8 to the surcharge term — both inflate the answer by a plausible-looking margin.
Gross, net, allowable: three numbers, one question
Three capacities describe one footing, and the stem’s wording picks which one it wants. Gross ultimate qult is the total pressure at failure, overburden included. Net ultimate qnet,ult = qult − γDf subtracts the overburden the soil already carried. Allowable divides by the factor of safety — gross allowable qall = qult/FS, net allowable qnet,all = qnet,ult/FS. The structural load is compared against the net allowable pressure (or, equivalently, the gross allowable load is Qall = qall × area, with the footing’s own weight and the backfill over it accounted for separately). When a stem says “the soil can safely support a pressure of” without qualifying it, it normally means net allowable — and the answer choices will include the gross value as bait.
General vs local shear failure
In dense sand and stiff clay the failure surface develops fully and suddenly — general shear — and Terzaghi’s factors apply directly. In loose sand and soft clay the surface never fully forms, the soil fails progressively, and it mobilises less than its full strength — local shear. Terzaghi handles this by reducing the strength parameters before looking up the factors: c′ = (2/3)c and φ′ = arctan((2/3) tan φ), then read reduced factors Nc′, Nq′, Nγ′ at φ′. The result is dramatic: local-shear capacity comes out at roughly one-third of the general-shear value for the same footing (Worked Problem 4 shows the ratio at 3.0). The exam signals local shear with the words “loose”, “soft”, or “local shear failure” — and when it does, the general-shear answer is sitting in the choices as the trap.
The water table: three cases
Water changes bearing capacity because submerged soil weighs less. The correction depends on where the water table sits relative to the footing, and the exam tests all three cases. Water table at or above the base: the soil above the base is submerged too, so the surcharge term uses γ′ as well as the self-weight term — the largest capacity cut. Water table at the base: the surcharge term keeps the moist γ (the soil above the base is dry), while the self-weight term uses γ′ = γsat − γw — about a 20% cut in sand (Worked Problem 3). Water table below the base but within about one footing width: use a weighted average unit weight in the self-weight term, interpolating between γ and γ′ by the depth of water within the wedge. Deeper than about B below the base: no effect — the failure wedge never reaches the water. The recurring slip is using γsat (the total weight) where γ′ (the effective weight) belongs: submerged soil pushes down with γ′, not γsat.
Worked problem 1 Strip footing on saturated clay, φ = 0 (FE pace, US units)
Given: a strip footing, B = 5 ft, embedment Df = 3 ft, on saturated clay with c = 1,200 psf, φ = 0, γ = 120 pcf. Factor of safety FS = 3. Find the ultimate and allowable bearing capacities.
Solution:
- At φ = 0 the factors are Nc = 5.7, Nq = 1.0, Nγ = 0.0 — read straight from the table.
- Cohesion term: c Nc = 1,200 × 5.7 = 6,840 psf
- Surcharge term: γDf Nq = 120 × 3 × 1.0 = 360 psf
- Self-weight term: ½ γB Nγ = 0 — the Nγ = 0 at φ = 0 kills the whole term, whatever B is.
- qult = 6,840 + 360 + 0 = 7,200 psf = 7.20 ksf; qall = 7,200/3 = 2,400 psf = 2.40 ksf
Answer: qult ≈ 7.20 ksf, qall ≈ 2.40 ksf. Trap note: on a φ = 0 problem the footing width B is a red herring — it appears only in the self-weight term, which is zero. Any answer choice that grows with B was built from a non-zero Nγ.
Worked problem 2 Square footing on sand — gross, net, and total load (FE pace, US units)
Given: a square footing, B = 6 ft, Df = 4 ft, on clean sand with c = 0, φ = 30°, γ = 115 pcf. Factors for φ = 30°: Nc = 37.2, Nq = 22.5, Nγ = 19.7. FS = 3. Find qult, the net allowable pressure, and the allowable total load.
Solution:
- Square shape factors: sc = 1.3, sγ = 0.8. (The cohesion term is zero here, so sc never enters — but the 0.8 does.)
- Surcharge term: γDf Nq = 115 × 4 × 22.5 = 10,350 psf
- Self-weight term: 0.8 × ½ × 115 × 6 × 19.7 = 0.4 × 115 × 6 × 19.7 = 5,437 psf
- qult = 0 + 10,350 + 5,437 = 15,787 psf ≈ 15.8 ksf
- Net ultimate: qnet,ult = 15,787 − γDf = 15,787 − 460 = 15,327 psf; net allowable = 15,327/3 = 5,109 psf ≈ 5.11 ksf
- Allowable total load (gross): Qall = (15,787/3) × 6 × 6 = 5,262 × 36 = 189,446 lb ≈ 189 kips
Answer: qult ≈ 15.8 ksf, qnet,all ≈ 5.11 ksf, Qall ≈ 189 kips. Trap note: 5,262 psf is the gross allowable — if the stem asks for the pressure the structure may add, the answer is the net 5,109 psf, not the gross. The two differ by only 3% here, which is exactly why the exam offers both.
Worked problem 3 Water table at the footing base (PE pace, US units)
Given: the same square footing as Problem 2 in shape — B = 6 ft, Df = 3 ft, sand with φ = 30°, c = 0 — but now the water table sits exactly at the footing base. Above the base γ = 120 pcf; below it γsat = 125 pcf, so γ′ = 125 − 62.4 = 62.6 pcf. Find qult and compare with the dry case.
Solution:
- Surcharge term — the soil above the base is still moist, so it keeps γ = 120 pcf: γDf Nq = 120 × 3 × 22.5 = 8,100 psf
- Self-weight term — the failure wedge sits below the water table, so it uses γ′ = 62.6 pcf: 0.4 × 62.6 × 6 × 19.7 = 2,960 psf
- qult = 0 + 8,100 + 2,960 = 11,060 psf ≈ 11.1 ksf
- Dry comparison (same footing, γ = 120 pcf throughout): qult = 8,100 + 0.4 × 120 × 6 × 19.7 = 8,100 + 5,674 = 13,774 psf
Answer: qult ≈ 11.1 ksf — about 20% below the dry 13.8 ksf. Trap note: the cut comes entirely from the third term (5,674 → 2,960 psf); the surcharge term is untouched because the soil above the base is dry. Using γ′ in both terms, or γsat in the third, are the two wrong answers the exam will offer.
Worked problem 4 Local shear failure in loose soil (PE pace, US units)
Given: a strip footing, B = 5 ft, Df = 4 ft, on loose soil with c = 600 psf, φ = 25°, γ = 115 pcf. General-shear factors for φ = 25°: Nc = 25.1, Nq = 12.7, Nγ = 9.7. The reduced friction angle is φ′ = 15°, with reduced factors Nc′ = 12.9, Nq′ = 4.4, Nγ′ = 2.5. Find the ultimate capacity under local shear, and compare with general shear.
Solution:
- Reduce the cohesion: c′ = (2/3) × 600 = 400 psf
- Local-shear capacity: q′ult = 400 × 12.9 + 115 × 4 × 4.4 + 0.5 × 115 × 5 × 2.5 = 5,160 + 2,024 + 719 = 7,903 psf ≈ 7.90 ksf
- General-shear capacity for comparison: qult = 600 × 25.1 + 115 × 4 × 12.7 + 0.5 × 115 × 5 × 9.7 = 15,060 + 5,842 + 2,789 = 23,691 psf ≈ 23.7 ksf
- Ratio: 23,691/7,903 ≈ 3.0 — local shear costs about two-thirds of the capacity.
Answer: q′ult ≈ 7.90 ksf under local shear (versus 23.7 ksf general). Trap note: the 23.7 ksf general-shear number is the bait — it is the answer you get by ignoring the word “loose” in the stem. Note also that the reduction applies to c and φ: reducing only one of them lands between the two values, which is where the other distractors sit.
Worked problem 5 Square footing on sand (SI units)
Given: a square footing, B = 2.0 m, Df = 1.0 m, on sand with c = 0, φ = 30°, γ = 18 kN/m³. Factors for φ = 30°: Nc = 37.2, Nq = 22.5, Nγ = 19.7. FS = 3. Find qult, the net allowable pressure, and the allowable total load.
Solution:
- Square shape factors: sc = 1.3, sγ = 0.8.
- Surcharge term: γDf Nq = 18 × 1.0 × 22.5 = 405.0 kN/m²
- Self-weight term: 0.4 × 18 × 2.0 × 19.7 = 283.7 kN/m²
- qult = 0 + 405.0 + 283.7 = 688.7 kN/m²
- Net allowable: qnet,all = (688.7 − 18 × 1.0)/3 = 670.7/3 = 223.6 kN/m²; allowable total load Qall = (688.7/3) × 2.0 × 2.0 = 229.6 × 4 = 918 kN
Answer: qult ≈ 689 kN/m², qnet,all ≈ 224 kN/m², Qall ≈ 918 kN. Trap note: kN/m² and kPa are the same unit — if a stem mixes kPa with N/m², convert before comparing. And as in Problem 2, the gross allowable (229.6 kN/m²) is not the net allowable (223.6 kN/m²); the exam offers both.
Frequently asked questions
What is Terzaghi's bearing capacity equation?
For a strip footing: qult = c·Nc + q·Nq + ½·γ·B·Nγ, where q = γ·Df is the overburden pressure at foundation level and the N-factors depend only on φ. Shape factors scale the cohesion and self-weight terms for square and circular footings.
What is the difference between gross and net bearing capacity?
Gross ultimate capacity qult is the total pressure at failure, including the weight of the soil already sitting above the footing base. Net ultimate capacity subtracts that overburden: qnet,ult = qult − γDf. The structure’s load is compared against the net allowable pressure, because the soil was already carrying its own weight before the footing was built.
How does the water table change bearing capacity?
Soil below the water table weighs less in effective terms, so use the submerged unit weight γ′ = γsat − γw in the self-weight term whenever the failure wedge sits below the water table. If the water table is at or above the footing base, the surcharge term uses γ′ too. A water table at the footing base typically cuts ultimate capacity by about 20% in sand.
What is local shear failure, and when does it apply?
In loose sand or soft clay the failure surface never fully develops, so the soil mobilises less than its full strength. Terzaghi handles this by reducing the strength parameters — c′ = (2/3)c and φ′ = arctan((2/3) tan φ) — then reading reduced bearing-capacity factors at φ′. Local-shear capacity comes out at roughly one-third of the general-shear value for the same footing.
What shape factors apply to square and circular footings?
Terzaghi’s shape factors are: strip sc = 1.0, sγ = 1.0; square sc = 1.3, sγ = 0.8; circular sc = 1.3, sγ = 0.6. They multiply the cohesion term (sc) and the self-weight term (sγ); the surcharge term takes no shape factor. Applying square factors to a strip footing is a favourite exam distractor.
How do I size a footing from a column load?
Set the allowable total load equal to the allowable pressure times the footing area: Qall = qall × B² for a square footing. Because qall itself grows with B through the ½γB Nγ term, the equation is quadratic in B — solve it, round the width up to the next practical size, and re-check. Always check the net allowable pressure against the structural load, not the gross value.
Free FE/PE flashcards + study tips, by email
Join the Water Resources Hub email list and get the free 40 water-resources flashcards (PDF + Anki) straight away, then study tips and practice problems by email. Email address only — no spam, unsubscribe any time.